{"id":3857,"date":"2026-11-22T00:49:15","date_gmt":"2026-11-21T16:49:15","guid":{"rendered":"http:\/\/www.canningscreditunion.com\/blog\/?p=3857"},"modified":"2026-11-22T00:49:15","modified_gmt":"2026-11-21T16:49:15","slug":"what-is-the-difference-between-axial-and-centrifugal-ip55-fans-401d-bf0cbe","status":"publish","type":"post","link":"http:\/\/www.canningscreditunion.com\/blog\/2026\/11\/22\/what-is-the-difference-between-axial-and-centrifugal-ip55-fans-401d-bf0cbe\/","title":{"rendered":"What is the difference between axial and centrifugal IP55 fans?"},"content":{"rendered":"<p>If you\u2019ve ever stood near a commercial cooler, a ventilation system in a factory, or a specialized cooling unit for sensitive outdoor gear, you\u2019ve probably felt the push of an IP55 fan at work. IP55 rating means these fans are protected against dust intrusion (not enough to stop fine dust over long periods, but enough for most industrial and outdoor settings) and can withstand low-pressure water jets from any direction\u2014perfect for spaces where moisture, dirt, or accidental splashes are common. As a supplier focused on axial IP55 fans, I get asked all the time how our lineup stacks up against centrifugal IP55 fans, and why choosing one over the other makes a huge difference for performance, cost, and longevity. I\u2019ve worked with both designs for over a decade, helping factories, refrigeration firms, and outdoor equipment manufacturers pick the right fan for their exact needs, and I\u2019m breaking down the key differences here so you don\u2019t have to guess. <a href=\"https:\/\/www.pbmmf.com\/waterproof-ip55-fan\/ip55-axial-fan\/\">IP55 Axial Fan<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.pbmmf.com\/uploads\/49133\/small\/48x252mm-ac-cross-flow-fan-pc48b2a252b75e87.jpg\"><\/p>\n<p>First, let\u2019s start with the core design: axial fans move air parallel to the axis of the fan\u2019s shaft, while centrifugal fans push air perpendicular to that axis. That might sound like basic mechanical 101, but it\u2019s the root of every other difference. For an axial IP55 fan, the blades sit on a central hub, spinning to pull air straight through the fan casing\u2014think of a giant version of a desk fan, but built to keep dust and moisture out. Centrifugal IP55 fans, by contrast, use a curved impeller wheel inside a spiral-shaped housing, which draws air in from the side and flings it outward, redirecting that air into a duct or a tighter airflow path.<\/p>\n<p>That design translates directly to airflow and pressure. Axial fans excel at moving large volumes of air at low pressure. If you\u2019re trying to cool a wide, open space\u2014like a warehouse loading dock, a condenser unit for walk-in coolers, or a greenhouse\u2014an axial IP55 fan is ideal. For example, when I worked with a mid-sized food processing plant last year, they needed to replace old outdoor exhaust fans that were struggling to circulate air in their open production bay during summer. Their old units delivered about 12,000 cubic feet per minute (CFM) but only could push air a few feet before it lost momentum. Swapping in our 18-inch axial IP55 fans bumped their airflow to 14,500 CFM, and because they move air in a straight line, it covered the entire 5,000-square-foot bay without needing extra ductwork. Centrifugal fans, on the other hand, handle high static pressure. Static pressure is the resistance air faces when moving through a duct, a narrow gap, or around obstacles. If you\u2019re routing air through a 100-foot duct, or need to push air through a filter or radiator, a centrifugal IP55 fan will outperform an axial fan every time. Last quarter, a manufacturer of outdoor telecommunications equipment reached out because their equipment cabinets kept overheating. The cabinets required air to travel through a 75-foot duct and through a fine dust filter, creating high static pressure. Their original axial fans could only move 8,000 CFM before stalling because they couldn\u2019t overcome the duct resistance. Switching to a centrifugal IP55 fan for that application solved the overheating issue immediately, even though it delivered slightly less total CFM (9,200 CFM) \u2014 because that air stayed pressurized all the way through the duct to cool the equipment.<\/p>\n<p>Next up: energy efficiency and noise, two factors that are make-or-break for most operations. Axial IP55 fans are generally more energy-efficient for low-pressure, high-volume tasks. Because their design has fewer moving parts and less drag when moving air straight, they use less power to move more air. The food processing plant I mentioned earlier saved about 18% on their monthly electricity bill after switching to axial IP55 fans, compared to their old centrifugal fans that they\u2019d used in the past. Noise is another big one. Axial fans tend to be noisier than centrifugal fans at the same CFM, especially at higher speeds. That\u2019s because the straight-line airflow creates more turbulence, which translates to noise. If you\u2019re installing fans near workstations or in spaces where noise levels matter\u2014like office areas attached to a warehouse, or outdoor dining patios where a ventilation fan is nearby\u2014centrifugal fans can be a better pick. They move air in a circular pattern inside the housing, which reduces turbulence, so they operate quieter. That same food plant, for example, tried centrifugal fans first and complained about 78 decibels of noise right near their production line, which was louder than their OSHA limit for that space. Axial fans, by comparison, operated at 68 decibels, which was well within their safety guidelines. Don\u2019t get me wrong: both can be noisy if not sized right, but axial\u2019s noise profile is far more suited for open, unobstructed areas, while centrifugal\u2019s lower turbulence makes it better for contained, duct-based spaces.<\/p>\n<p>Durability and application flexibility are also key when you\u2019re dealing with IP55-rated equipment. The IP55 rating means both types are resistant to water jets and dust, but their design makes them better for different environments. Axial IP55 fans are more compact and have a simpler casing, which means there are fewer crevices where dust or moisture can get trapped\u2014though their open front design does mean they\u2019re more prone to debris hitting the blades. That\u2019s why we recommend adding a simple grille for outdoor axial fans, which is an easy, low-cost upgrade. They\u2019re also easier to maintain: if a blade gets damaged, you can swap it out without removing the entire casing, and the motor is exposed enough to clean without full disassembly. Centrifugal IP55 fans, by contrast, have a closed impeller inside a housing, which protects the blades from outside debris, but that housing can trap moisture or dust inside if it\u2019s not properly sealed. For that reason, we always advise a yearly pressure test to make sure the housing seals are intact, especially in coastal or high-humidity areas where salt air can seep in. Another durability point: axial fans tend to last longer in continuous-use applications. We have axial IP55 fans running in a Florida airport\u2019s outdoor luggage area that\u2019s been operating 24\/7 for 7 years, with only a bearing replacement needed. Their centrifugal fans in the same space, used for ducting air to the restrooms, needed a housing seal replacement after 4 years because of saltwater corrosion.<\/p>\n<p>Cost is another factor that often surprises people. Axial IP55 fans are almost always cheaper upfront, and cheaper to maintain over time. The food plant I worked with paid about $450 per axial fan, compared to $700 per centrifugal fan for the same airflow. Maintenance costs for axial fans are also lower: we charge about $120 a year per fan for cleaning and bearing checks, versus $200 a year for centrifugal fans, because they require more seal and housing checks. That said, centrifugal fans can save money in the long run in specific applications. If you\u2019re dealing with high static pressure, a centrifugal fan won\u2019t have to run at high speeds to move air, which means lower energy costs over time. The telecommunications equipment manufacturer I mentioned earlier, for example, calculated that their annual energy cost for the centrifugal fan was $350, compared to $520 for an axial fan that would have needed to run 20% faster to push air through the duct, making the centrifugal fan more cost-effective long-term, even with the higher upfront price.<\/p>\n<p>Common misconceptions trip up a lot of people when choosing between these two fans. The biggest one is that \u201cbigger CFM is always better.\u201d That\u2019s only true if you\u2019re moving air through an unobstructed space. If you have ductwork, a narrow gap, or a filter, CFM alone doesn\u2019t matter\u2014static pressure does. Another misconception is that all IP55 fans are the same. I\u2019ve seen clients try to use a standard IP55 axial fan for a duct application, only to have it fail in a week because it couldn\u2019t handle the pressure. The IP55 rating only covers ingress protection, not performance or design, so you have to match the fan\u2019s design to your specific airflow needs.<\/p>\n<p>At the end of the day, the choice between axial and centrifugal IP55 fans comes down to three questions: How much space am I cooling? Do I need to move air through ducts or obstacles? What\u2019s my noise and budget priority? If you\u2019re cooling a large, open outdoor space, a greenhouse, or a condenser unit with no ductwork, axial IP55 fans are the clear pick\u2014affordable, efficient, and easy to maintain. If you\u2019re routing air through ducting, cooling equipment with narrow gaps, or need lower noise levels in a contained space, centrifugal IP55 fans will deliver more consistent performance.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.pbmmf.com\/uploads\/49133\/small\/146mm-waterproof-ip55-ec-ac-forward-curved2f929.jpg\"><\/p>\n<p>If you\u2019re still not sure which fan is right for your operation, feel free to reach out to our team to discuss your project in detail. We can help you match the right fan to your space, budget, and performance needs, whether that\u2019s an axial IP55 fan, a centrifugal model, or another specialized cooling solution.<\/p>\n<p><a href=\"https:\/\/www.pbmmf.com\/dual-inlet-blower\/\">Dual Inlet Blower<\/a> References:<br \/>\nASHRAE Handbook &#8211; HVAC Systems and Equipment, 2020.<br \/>\nFan and Blower Application Engineering, 3rd Edition, Air Movement and Control Association International, 2018.<br \/>\nIP Code Definitions for Enclosure Protection, International Electrotechnical Commission Standard 60529, 2021.<br \/>\nIndustrial Ventilation: A Manual of Recommended Practice, American Conference of Governmental Industrial Hygienists, 2022.<\/p>\n<hr>\n<p><a href=\"https:\/\/www.pbmmf.com\/\">PBM Motor and Fan (Suzhou) Co., Ltd.<\/a><br \/>PBM Motor and Fan (Suzhou) Co., Ltd. is one of the most professional ip55 axial fan manufacturers and suppliers in China, featured by quality products and good price. Please rest assured to buy customized ip55 axial fan made in China here from our factory. Welcome to contact us for quotation.<br \/>Address: No.8 Zhu Street, Weiting Town, Suzhou Industrial Park China 215121<br \/>E-mail: sales@pbmmf.com<br \/>WebSite: <a href=\"https:\/\/www.pbmmf.com\/\">https:\/\/www.pbmmf.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019ve ever stood near a commercial cooler, a ventilation system in a factory, or a &hellip; <a title=\"What is the difference between axial and centrifugal IP55 fans?\" class=\"hm-read-more\" href=\"http:\/\/www.canningscreditunion.com\/blog\/2026\/11\/22\/what-is-the-difference-between-axial-and-centrifugal-ip55-fans-401d-bf0cbe\/\"><span class=\"screen-reader-text\">What is the difference between axial and centrifugal IP55 fans?<\/span>Read more<\/a><\/p>\n","protected":false},"author":331,"featured_media":3857,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3820],"class_list":["post-3857","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-ip55-axial-fan-4e71-c00028"],"_links":{"self":[{"href":"http:\/\/www.canningscreditunion.com\/blog\/wp-json\/wp\/v2\/posts\/3857","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.canningscreditunion.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.canningscreditunion.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.canningscreditunion.com\/blog\/wp-json\/wp\/v2\/users\/331"}],"replies":[{"embeddable":true,"href":"http:\/\/www.canningscreditunion.com\/blog\/wp-json\/wp\/v2\/comments?post=3857"}],"version-history":[{"count":0,"href":"http:\/\/www.canningscreditunion.com\/blog\/wp-json\/wp\/v2\/posts\/3857\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.canningscreditunion.com\/blog\/wp-json\/wp\/v2\/posts\/3857"}],"wp:attachment":[{"href":"http:\/\/www.canningscreditunion.com\/blog\/wp-json\/wp\/v2\/media?parent=3857"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.canningscreditunion.com\/blog\/wp-json\/wp\/v2\/categories?post=3857"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.canningscreditunion.com\/blog\/wp-json\/wp\/v2\/tags?post=3857"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}